Step Up Oil Immersed Transformer

Step Up Oil Immersed Transformer

Rated capacity: 30kVA-2500kVA.
Input voltage: 6kV, 10kV, 15kV, 20kV, or 35kV.
The Step Up Oil Immersed Transformer is used when the output voltage from equipment or a generation system must be raised before power is sent to a line or grid point.

A Step Up Oil Immersed Transformer is a transformer that raises voltage from a lower level to a higher level for power delivery. It can be used after generation equipment, solar inverter groups, industrial power systems, or other sites where the outgoing line needs a higher voltage. The oil immersed structure helps carry heat away from the winding and gives stable insulation between voltage levels. In real project work, the important checks are input voltage, output voltage, capacity, vector group, cooling, and daily load changes. These details decide whether the transformer will run smoothly after connection.

 

Product Parameters

 

Parameter

Value

Phase

Three phase

Input voltage

6kV / 10kV / 15kV / 20kV / 35kV

Output voltage

110V / 220V / 380V / 400V / 440V / 480V

Rated capacity

30kVA-2500kVA

Frequency

50/60Hz

Vector group

Dyn11 / Yyn0

Cooling method

ONAN

Winding material

100% copper

Standard

IEC / ISO / CE / ANSI / IEEE

Warranty

2 years

Main Applications

 

1. Solar or generation projects that need voltage raised before grid connection.

2. Industrial systems where outgoing voltage must match the site line.

3. Temporary or permanent power stations with medium voltage output demand.

 

Components

 

Main parts include oil tank, laminated core, high and low voltage winding, transformer oil, bushings, tap changer, radiator or corrugated tank, and protection accessories. The Step Up Oil Immersed Transformer should be checked with the inverter or generator side data before final drawing.

 

_20260123092254.png
_20260123092302.png
3.jpg
FAQ

Q: Can it be used for solar projects?

A: Yes. It can be used when the inverter output needs to be stepped up, but the inverter voltage and grid requirement must be clear.

Q: What should be checked in load data?

A: Daily output change, peak power, temperature, cable length, and protection plan should be reviewed.

Q: Does it need a special base?

A: A stable base is needed. For a Step Up Oil Immersed Transformer, oil containment and lifting space are also useful points to confirm.

 

 

 

Hot Tags: step up oil immersed transformer, China step up oil immersed transformer manufacturers, suppliers, factory, 3 phase oil transformer, Amorphous Metal Transformer, oil filled distribution transformers, Oil Immersed Hermetically Sealed Type Transformer, oil immersed power transformer, oil immersed transformer