Pad Mounted Oil Immersed Transformer

Pad Mounted Oil Immersed Transformer

Rated capacity: 30kVA-2500kVA.
Input voltage: 6kV, 10kV, 15kV, 20kV, or 35kV.
The Pad Mounted Oil Immersed Transformer is used in outdoor distribution points where the transformer needs a clean ground layout and an enclosed service area.

A Pad Mounted Oil Immersed Transformer is a ground installed transformer used for commercial blocks, small industrial yards, and public power distribution. It places the oil immersed transformer body and connection points in a compact arrangement, so the site does not need a tall pole frame or a large transformer room. The oil gives insulation and heat transfer, while the sealed metal tank helps the unit work in outdoor weather. This product is useful when the installer wants easier cable access, safer ground service, and a neat appearance near buildings or roads.

 

Product Parameters

 

Parameter

Value

Phase

Three phase

Input voltage

6kV / 10kV / 15kV / 20kV / 35kV

Output voltage

110V / 220V / 380V / 400V / 440V / 480V

Rated capacity

30kVA-2500kVA

Frequency

50/60Hz

Vector group

Dyn11 / Yyn0

Cooling method

ONAN

Winding material

100% copper

Standard

IEC / ISO / CE / ANSI / IEEE

Warranty

2 years

Main Applications

 

1. Residential and commercial distribution points with limited space.

2. Small industrial yards that need a ground mounted transformer near the load.

3. Outdoor cable entry areas where a pole layout is not convenient.

 

Use Notes

 

_20260123092254.png

1. Check the concrete base size before delivery.

2. Keep enough door opening space for cable work and inspection.

3. Confirm earthing, cable direction, and protective fence rules before installation.

For a Pad Mounted Oil Immersed Transformer, site drawings should show the cable entry side, pad size, and service door space before production starts.

FAQ

Q: Where is it normally installed?

A: It is normally placed on a concrete pad near the load point. The Pad Mounted Oil Immersed Transformer should have enough space for door opening, cable bending, and inspection.

Q: Can it be used outdoors?

A: Yes. The tank and enclosure are made for outdoor work, but drainage, grounding, and site protection still need to be checked.

Q: What information is needed before order?

A: Capacity, voltage, cable direction, enclosure layout, and local standard should be confirmed first.

 

 

 

Hot Tags: pad mounted oil immersed transformer, China pad mounted oil immersed transformer manufacturers, suppliers, factory, amorphous core type transformer, amorphous steel core, oil filled power transformer, oil immersed distribution transformer, oil immersed type transformer, transformer oil price

Send Inquiry