Hermetically Sealed Oil Immersed Transformer

Hermetically Sealed Oil Immersed Transformer

Rated capacity: 30kVA-2500kVA. Input voltage: 6kV, 10kV, 15kV, 20kV, or 35kV. The Hermetically Sealed Oil Immersed Transformer uses a sealed tank design to reduce contact between transformer oil and outside air during normal operation.

A Hermetically Sealed Oil Immersed Transformer is an oil immersed transformer with a sealed tank structure. The design helps keep the oil away from outside air and moisture, so the oil condition can stay more stable during service. It is used in distribution projects where the owner wants less daily oil handling and a cleaner tank arrangement. The corrugated or sealed tank can absorb oil expansion by its own structure, depending on design. This product still needs normal checks, but it reduces some open-breathing concerns seen in older transformer layouts.

 

Product Parameters

 

Parameter

Value

Phase

Three phase

Input voltage

6kV / 10kV / 15kV / 20kV / 35kV

Output voltage

110V / 220V / 380V / 400V / 440V / 480V

Rated capacity

30kVA-2500kVA

Frequency

50/60Hz

Vector group

Dyn11 / Yyn0

Cooling method

ONAN

Winding material

100% copper

Standard

IEC / ISO / CE / ANSI / IEEE

Warranty

2 years

Components

 

The unit can include sealed oil tank, core, winding, transformer oil, bushings, tap changer, pressure relief part, thermometer, and lifting lugs. For a Hermetically Sealed Oil Immersed Transformer, tank sealing and oil level checking should be handled carefully before shipment.

 

Product Advantages

The sealed structure helps limit moisture contact with transformer oil.

The tank arrangement can reduce routine oil exposure during service.

It is suitable for outdoor distribution points and plant power systems.

 

3
4
5
 

 

FAQ

Q: Does sealed mean no inspection?

A: No. Sealed design reduces some oil contact, but visual checking, temperature checking, and regular maintenance are still needed.

Q: Where can it be installed?

A: It can be used in outdoor distribution, industrial sites, and substations when the model matches site voltage and capacity.

Q: What should be checked before delivery?

A: For a Hermetically Sealed Oil Immersed Transformer, sealing surface, oil filling, accessories, and test report should be checked.

 

 

 

 

Hot Tags: hermetically sealed oil immersed transformer, China hermetically sealed oil immersed transformer manufacturers, suppliers, factory, 3 phase oil transformer, 750 kva oil filled transformer, ester filled transformers, oil immersed type transformer, oil immersed power transformer, oil-immersed transformer

Send Inquiry