What are the installation requirements for dry type transformers in pharmaceutical factories?

Aug 19, 2025Leave a message

Dry type transformers are essential electrical equipment in pharmaceutical factories, ensuring a stable and reliable power supply for various production processes. As a dry type transformer supplier, I understand the importance of proper installation to guarantee the safety and efficiency of these transformers. In this blog, I will discuss the installation requirements for dry type transformers in pharmaceutical factories.

Environmental Requirements

Temperature and Humidity

Pharmaceutical factories often have strict environmental control requirements. Dry type transformers should be installed in an environment where the ambient temperature is between -5°C and 40°C. High temperatures can accelerate the aging of the insulation materials in the transformer, reducing its service life. On the other hand, extremely low temperatures may cause the insulation to become brittle and crack.

The relative humidity should not exceed 95% (non - condensing). Excessive humidity can lead to moisture absorption by the insulation materials, which may result in electrical breakdown and short - circuits. To maintain the appropriate humidity level, dehumidifiers can be installed in the transformer room if necessary.

Cleanliness

The installation site should be clean and free from dust, corrosive gases, and flammable substances. Pharmaceutical production involves various chemicals and powders, and any dust or corrosive particles can adhere to the transformer's surface and insulation, degrading its performance. For example, sulfur dioxide and other acidic gases can corrode the metal parts of the transformer. Therefore, the transformer room should be well - sealed and equipped with air - filtration systems to ensure a clean environment.

Location and Space Requirements

Location Selection

The dry type transformer should be installed in a well - ventilated area. Adequate ventilation is crucial for dissipating the heat generated during the operation of the transformer. It is recommended to place the transformer near exterior walls or in areas with natural ventilation channels. Avoid installing the transformer in a confined space or near heat - generating equipment such as boilers.

In addition, the location should be easily accessible for maintenance and inspection. There should be sufficient space around the transformer for technicians to perform routine checks, repairs, and replacements of components.

Space Requirements

Sufficient space around the transformer is necessary for proper operation and safety. The clearance between the transformer and the surrounding walls should be at least 800mm on each side to ensure good air circulation. The top clearance should be at least 1000mm to allow for the upward flow of hot air.

Moreover, there should be enough space in front of the transformer for the opening of doors and access to control panels. A minimum of 1500mm of clear space in front of the transformer is recommended.

Mounting Requirements

Foundation

The transformer should be mounted on a solid and level foundation. The foundation should be able to support the weight of the transformer and any additional loads during operation. The surface of the foundation should be flat, with a levelness tolerance of no more than 5mm per meter. Reinforced concrete is a commonly used material for the foundation.

Mounting Method

Dry type transformers can be mounted on brackets or directly on the foundation. When using brackets, the brackets should be firmly fixed to the foundation and have sufficient strength to support the transformer. The mounting bolts should be tightened to the specified torque to prevent the transformer from vibrating or moving during operation.

Electrical Connection Requirements

Cable Selection

The cables used for connecting the dry type transformer should have appropriate cross - sectional areas to carry the rated current of the transformer without overheating. The cable insulation should be suitable for the operating voltage and environmental conditions. For example, in a pharmaceutical factory, where there may be exposure to chemicals and moisture, cables with high - quality insulation materials such as cross - linked polyethylene (XLPE) are recommended.

Connection Terminals

The connection terminals of the transformer should be clean and free from oxidation. Before making the connections, the terminals should be thoroughly cleaned with a suitable cleaning agent. The cables should be securely connected to the terminals using appropriate connectors, and the connections should be tightened to ensure good electrical contact. Loose connections can cause overheating and electrical arcing, which may damage the transformer and pose a safety hazard.

Grounding

Proper grounding is essential for the safety of the dry type transformer. The transformer should be grounded using a dedicated grounding conductor with a cross - sectional area not less than the requirements specified in the electrical codes. The grounding system should be connected to a reliable grounding electrode, such as a grounding rod or a grounding grid. This helps to protect the transformer and personnel from electrical shocks in case of a fault.

Protection and Monitoring Requirements

Over - current and Over - voltage Protection

Dry type transformers in pharmaceutical factories should be equipped with over - current and over - voltage protection devices. These devices can automatically disconnect the transformer from the power supply when the current or voltage exceeds the rated values, preventing damage to the transformer. Circuit breakers and fuses are commonly used over - current protection devices, while surge arresters can be installed to protect against over - voltage caused by lightning or other transient events.

Temperature Monitoring

Temperature monitoring is crucial for the safe operation of dry type transformers. Temperature sensors can be installed inside the transformer to measure the temperature of the windings and core. When the temperature exceeds the set limit, an alarm signal can be sent to the control room, allowing technicians to take appropriate measures such as reducing the load or shutting down the transformer for inspection.

Our Product Offerings

As a dry type transformer supplier, we offer a wide range of high - quality dry type transformers to meet the specific needs of pharmaceutical factories. Our Air Insulated Dry Type Transformer provides excellent insulation performance and is suitable for clean and well - ventilated environments. The Dry Type Step Up Transformer can be used to increase the voltage level as required by the production equipment. And our Cast Resin Distribution Transformer offers high reliability and durability, with excellent resistance to moisture and chemicals.

air insulated dry type transformer (3)Cast Resin Distribution Transformer

If you are in the pharmaceutical industry and are looking for a reliable dry type transformer solution, we are here to help. Our team of experts can provide professional advice on installation, operation, and maintenance. We are committed to providing you with the best products and services to ensure the smooth operation of your pharmaceutical factory. Contact us today to discuss your specific requirements and start the procurement negotiation process.